TSSA=0, OCSB=0, OCSA=0, TSSAD=0, TSSB=0, OCSAD=0
A/D Conversion Extended Input Control Register
TSSAD | Temperature Sensor Output A/D converted Value Addition/Average Mode Select 0 (0): Temperature sensor output A/D-converted value addition/average mode is not selected. 1 (1): Temperature sensor output A/D-converted value addition/average mode is selected. |
OCSAD | Internal Reference Voltage A/D converted Value Addition/Average Mode Select 0 (0): Internal reference voltage A/D-converted value addition/average mode is not selected. 1 (1): Internal reference voltage A/D-converted value addition/average mode is selected. |
Reserved | These bits are read as 000000. The write value should be 000000. |
TSSA | Temperature Sensor Output A/D Conversion Select 0 (0): The temperature sensor output is not selected. 1 (1): The temperature sensor output is selected. |
OCSA | Internal Reference Voltage A/D Conversion Select 0 (0): The internal reference voltage is not selected. 1 (1): The internal reference voltage is selected for group A in single scan mode, continuous scan mode, or group scan mode. |
TSSB | Temperature Sensor Output A/D Conversion Select for Group B 0 (0): The temperature sensor output is not selected. 1 (1): The temperature sensor output is not selected for group B in group scan mode. |
OCSB | Internal Reference Voltage A/D Conversion Select for Group B 0 (0): The internal reference voltage is not selected. 1 (1): The internal reference voltage is selected for group B in group scan mode. |
Reserved | This bit is read as 0. The write value should be 0. |
Reserved | This bit is read as 0. The write value should be 0. |
Reserved | This bit is read as 0. The write value should be 0. |